Доставка из Европы. MODEL Aquilion 64 X-RAY TUBE X-RAY TUBE ANODE Heat storage, hu (X-ray tube anode) 7500000 Heat dissipation rate, hu/min (X-RAY TUBE) 1,386,000 max Tube cooling (X-ray tube anode) Oil/air Tube focal spot, mm (X-ray tube anode) 1.6 x 1.4, 0.9 x 0.8 (IEC standard) POWER NEEDED 200 VAC, 50/60 Hz, 3-phase Type (CONFIGURATION) Multislice helical # of slices (X-ray tube anode) 64 TABLE FEATURES Range of movement Vertical, cm (Range of movement) 31-94.4 Longitudinal, cm (Range of movement) 219 Scanning range,cm (Range of movement) 180 Max. patient weight, (precision), kg (Range of movement) 205 (±0.25 mm) Image storage Hd capacity, gb (IMAGE STORAGE) 180, 720 raw data, max 3,600 rotations No. online images (IMAGE STORAGE) 160000 Archive (IMAGE STORAGE) 9.4 GB DVD-RAM GENERATOR Output, kw (X-RAY GENERATORS) 60 Kvp range (GENERATOR) 80,100,120, 135 Ma range (IMAGING SYSTEM) 1010-50 in 5 mA steps DICOM 3.0 COMPATIBLE (POWER NEEDED, VAC) Yes PERFORMANCE Minimum interscan time, sec (PERFORMANCE) 0 Dynamic scan pace (PERFORMANCE) 200 scans/100 sec High-contrast spatial resolution 0% mtf, lp/cm (PERFORMANCE) 18 50% mtf, lp/cm (PERFORMANCE) 8 Low-contrast resolution, mm at % at lt;=4 rads (PERFORMANCE) 2 at 0.3% Sound, % at lt;= 2.5 rads (PERFORMANCE) lt;0.5 DISPLAY MONITOR 18quot; LCD color x 2 Matrixes, pixels (DISPLAY) 1280 x 1024 Range of ct numbers (DISPLAY) -1,536 to +8,191 Image enlarging scale (DISPLAY) Up to 20x Max # slices displayed simultaneously (DISPLAY) 16 HELICAL SCANNING (DISPLAY) Yes Max scan time, sec (DISPLAY) 100 Max scan volume, cm (DISPLAY) 175 Spatial resolution, lp/cm (DISPLAY) 18 at 0% MTF Pitch (DISPLAY) 0.8-96 mm/sec couch-top speed Reconstruction time per image, sec (DISPLAY) 0.1 FLOOR SPACE NEEDED Size, m2 (FLOOR SPACE NEEDED) 27 (25 short couch) SCORING OF CORONARY ARTERY CALCIFICATION (IMAGE STORAGE) Optional IMAGE PROCESSING (MAXIMUM DISPLAY) Cpu (NETWORK/DATABASE) 32-bit processor x 2 Scan fovs, cm (IMAGE PROCESSING) 18,24,32,40, 50 Image reconstruction matrixes (IMAGE PROCESSING) 512 x 512 Reconstruction time Per slice, sec (Reconstruction time) 0.1 For localization scan, sec (Reconstruction time) Real time GANTRY Geometry (GANTRY) Rotate-rotate, slip ring, multislice DETECTOR (SCATTERED LIGHT) Solid-state Rows (GANTRY) 64 Elements/row (GANTRY) 64 x 896 # detection channels (GANTRY) 64 x 896 Rotation times, sec 360 (GANTRY) 0.5,0.75,1,1.5,2, 3; optional 0.4 Partial (GANTRY) 0.32; optional 0.25 Slice thickness, mm (GANTRY) 0.5 x 64: 1 x 32; 2 x 16; 0.5,1,2,3,4,6, 8 (all x 4) X-ray fan beam angle, amp;#194;° (GANTRY) 49.2 Gantry angle deg (GANTRY) ±30 Gantry size, hxwxd,cm (GANTRY) 195 x 233 x 96 Gantry weight, kg (GANTRY) 1750 Gantry opening, cm (GANTRY) 72 Scan localizer (GANTRY) Laser OTHER ATTRIBUTES (Interference compensation) Cerebral blood-flow analysis syatem; quantitive bone mineral analysis; CT fluoro; full DICOM featue set; pediatric scanning; SureStart contrast tracking; SureScan real-time imaging;